D-122 TimeVault™ User’s Manual 6000-100AppD.fm Rev. D
Appendix D: SNMP – Simple Network Management Protocol Symmetricom SNMP Enterprise MIB
actsGoodCalls OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Number of times the time server called the ACTS dial-up service
and successfully received the time.”
::= { acts 7 }
actsBadCalls OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Number of times the time server called the ACTS dial-up service
and something was not right. This variable is the sum total of all
other ACTS failure types.”
::= { acts 8 }
actsFailedInit OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Time servers internal modem failed to initialize. If this is
excessive, it may indicate a time server hardware failure.”
::= { acts 9 }
actsNoDialTone OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Time servers internal modem found no dial tone. This may be
caused by a broken phone line to the time server.”
::= { acts 10 }
actsNoCarrier OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Time servers internal modem found no carrier. No modem was
found at the other end and maybe the phone number for ACTS is wrong.”
::= { acts 11 }
actsBusyLine OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Time servers internal modem found ACTS line busy.”
::= { acts 12 }